Eaton STS321120B301 ESD Suppressor 12 V 30 pF
Eaton STS321120B301 ESD Suppressor 12 V 30 pF

Eaton STS321120B301 ESD Suppressor 12 V 30 pF

Share
STS321120B301: 12 V standoff TVS diode array, 1-channel, 30 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321120B301 ESD Suppressor 12 V 30 pF

    STS321120B301 at a glance: TVS diode array ESD suppressor, 12 V standoff, 33 V clamp, 1 channel, 30 pF, 400 W.

    Specification Table

    ParameterValue
    Orderable part numberSTS321120B301
    Standoff voltage (VRWM)12 V
    Breakdown voltage (min / typ / max)13.3 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line400 W
    Clamping voltage at 1 A19 V
    Clamping voltage at 12 A33 V
    Junction capacitance at 1 MHz, per line30 pF typ / 45 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11151

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11151. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 12 A the clamp sits at 33 V, or 2.75 times the 12 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 400 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    30 pF per line is 5.3 ohms of reactance at 1 GHz and 53.1 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 12 V the part draws at most 1 uA, which is 12 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    Board Layout

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • ESD ratings are per IEC 61000-4-2 with the part as the first element the discharge meets. A connector shell or a mounting post that offers an easier path takes the strike instead, and the array never conducts.
    • The capacitance figure is at zero bias. At the working voltage the junction depletes and the value falls, so the loading on a live bus is lower than the table suggests.

    Frequently Asked Questions

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    Shenzhen Gaorunxin Technology Co., Ltd