Eaton STS321150U751 ESD Suppressor 15 V 75 pF
Eaton STS321150U751 ESD Suppressor 15 V 75 pF

Eaton STS321150U751 ESD Suppressor 15 V 75 pF

Share
STS321150U751: 15 V standoff TVS diode array, 1-channel, 75 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321150U751 ESD Suppressor 15 V 75 pF

    STS321150U751 at a glance: TVS diode array ESD suppressor, 15 V standoff, 23 V clamp, 1 channel, 75 pF, 350 W.

    Specification Table

    ParameterValue
    Orderable part numberSTS321150U751
    Standoff voltage (VRWM)15 V
    Breakdown voltage (min / typ / max)16 V / 17 V / 19 V
    Leakage current at VRWM0.2 uA max
    Peak pulse power, 8/20 us, per line350 W
    Clamping voltage at 1 A23 V
    Junction capacitance at 1 MHz, per line75 pF typ / 90 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11152

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11152. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    How to Read These Ratings

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    At 1 A the clamp sits at 23 V, or 1.53 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    75 pF per line is 2.1 ohms of reactance at 1 GHz and 21.2 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 15 V the part draws at most 0.2 uA, which is 3 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    Board Layout

    On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd