Eaton STS321360B141 ESD Suppressor 36 V 14 pF
Eaton STS321360B141 ESD Suppressor 36 V 14 pF

Eaton STS321360B141 ESD Suppressor 36 V 14 pF

Share
STS321360B141: 36 V standoff TVS diode array, 1-channel, 14 pF per line, SOD-323 (S32), commercial grade.
    • Product Details
    • Download

    Eaton STS321360B141 ESD Suppressor 36 V 14 pF

    STS321360B141 at a glance: TVS diode array ESD suppressor, 36 V standoff, 60 V clamp, 1 channel, 14 pF, 400 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTS321360B141
    Standoff voltage (VRWM)36 V
    Breakdown voltage (min / typ / max)40 V / 42 V / 47.6 V
    Leakage current at VRWM0.2 uA max
    Peak pulse power, 8/20 us, per line400 W
    Clamping voltage at 1 A60 V
    Junction capacitance at 1 MHz, per line14 pF typ / 25 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-323 (S32)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11151

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11151. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    At 1 A the clamp sits at 60 V, or 1.67 times the 36 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 400 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    14 pF per line is 11.4 ohms of reactance at 1 GHz and 114 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 36 V the part draws at most 0.2 uA, which is 7.2 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.

    Placement in the Circuit

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • A unidirectional array clamps one polarity at the breakdown and the other at a forward drop. That asymmetry is correct on a DC rail and wrong on a differential pair that swings below ground.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.