Eaton STS521033B950 TVS Diode 3.3 V 60 W
Eaton STS521033B950 TVS Diode 3.3 V 60 W

Eaton STS521033B950 TVS Diode 3.3 V 60 W

Share
STS521033B950: 3.3 V standoff TVS diode array, 1-channel, 9.5 pF per line, SOD-523 (S52), commercial grade.
    • Product Details
    • Download

    Eaton STS521033B950 TVS Diode 3.3 V 60 W

    STS521033B950 at a glance: TVS diode array ESD suppressor, 3.3 V standoff, 12 V clamp, 1 channel, 9.5 pF, 60 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS521033B950
    Standoff voltage (VRWM)3.3 V
    Breakdown voltage (min / typ / max)3.6 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line60 W
    Clamping voltage at 1 A8 V
    Clamping voltage at 4.5 A12 V
    Junction capacitance at 1 MHz, per line9.5 pF typ / 15 pF max
    Channels1
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11153

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11153. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    At 4.5 A the clamp sits at 12 V, or 3.64 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 60 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    9.5 pF per line is 16.8 ohms of reactance at 1 GHz and 168 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 3.3 V the part draws at most 1 uA, which is 3.3 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    Layout and Placement

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • Breakdown is specified at 1 mA. The spread between minimum and maximum is production tolerance, so the design margin is measured from the minimum, not the typical.

    Frequently Asked Questions

    Does the array capacitance disturb the signal?
    It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.

    Why does the package affect the rating?
    It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    Shenzhen Gaorunxin Technology Co., Ltd