| Parameter | Value |
|---|---|
| Orderable part number | STS521050B181AH |
| Standoff voltage (VRWM) | 5 V |
| Breakdown voltage (min / typ / max) | 5.5 V / 7 V / 8.5 V |
| Leakage current at VRWM | 0.1 uA max |
| Peak pulse power, 8/20 us, per line | 100 W |
| Clamping voltage at 1 A | 10 V |
| Clamping voltage at 7 A | 13 V |
| Junction capacitance at 1 MHz, per line | 18 pF typ / 20 pF max |
| Channels | 1 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOD-523 (S52) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +150 °C |
| Qualification | AEC-Q101 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1281 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data ELX1281. Values above are
read directly from the electrical table for this part number, not from the family
summary.
Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.
At 7 A the clamp sits at 13 V, or 2.60 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 100 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
18 pF per line is 8.8 ohms of reactance at 1 GHz and 88.4 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.
Standing at 5 V the part draws at most 0.1 uA, which is 0.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
Eaton builds these on a silicon avalanche process, so the clamp is sharp and the part recovers without the off-state drift a metal oxide varistor shows after a surge. The trade is a fixed breakdown window that the working voltage has to sit below with margin.
On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.
Does the array capacitance disturb the signal?
It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.
Why does the package affect the rating?
It sets the thermal mass and the lead inductance. The same die in a SOD-523 and a SOT-23 dissipates differently, so the package is part of the electrical choice rather than only a footprint decision.
Is the automotive suffix a different die?
It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.