STS521050U751: 5 V standoff TVS diode array, 1-channel, 75 pF per line, SOD-523 (S52), commercial grade.
    • Product Details
    • Download

    Eaton STS521050U751 TVS Diode 5 V 150 W

    STS521050U751 at a glance: TVS diode array ESD suppressor, 5 V standoff, 15 V clamp, 1 channel, 75 pF, 150 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTS521050U751
    Standoff voltage (VRWM)5 V
    Breakdown voltage (min / typ / max)6 V / 8 V
    Leakage current at VRWM0.1 uA max
    Peak pulse power, 8/20 us, per line150 W
    Clamping voltage at 1 A10 V
    Clamping voltage at 10 A15 V
    Junction capacitance at 1 MHz, per line75 pF typ / 100 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11159

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11159. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    Reading the Data Sheet

    The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.

    At 10 A the clamp sits at 15 V, or 3.00 times the 5 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 150 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    75 pF per line is 2.1 ohms of reactance at 1 GHz and 21.2 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 5 V the part draws at most 0.1 uA, which is 0.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    Layout and Placement

    Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.

    • ESD ratings are per IEC 61000-4-2 with the part as the first element the discharge meets. A connector shell or a mounting post that offers an easier path takes the strike instead, and the array never conducts.
    • The capacitance figure is at zero bias. At the working voltage the junction depletes and the value falls, so the loading on a live bus is lower than the table suggests.

    Frequently Asked Questions

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.