| Parameter | Value |
|---|---|
| Orderable part number | STS521070U701AH |
| Standoff voltage (VRWM) | 7 V |
| Breakdown voltage (min / typ / max) | 7.5 V / 8.5 V / 9.5 V |
| Leakage current at VRWM | 0.1 uA max |
| Peak pulse power, 8/20 us, per line | 120 W |
| Clamping voltage at 1 A | 13 V |
| Clamping voltage at 9 A | 16 V |
| Junction capacitance at 1 MHz, per line | 70 pF typ / 85 pF max |
| Channels | 1 |
| Polarity | Unidirectional |
| ESD capability, IEC 61000-4-2 | +/-30 kV contact / +/-30 kV air |
| Package | SOD-523 (S52) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +150 °C |
| Qualification | AEC-Q101 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1281 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data ELX1281. Values above are
read directly from the electrical table for this part number, not from the family
summary.
The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.
At 9 A the clamp sits at 16 V, or 2.29 times the 7 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 120 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
70 pF per line is 2.3 ohms of reactance at 1 GHz and 22.7 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.
Standing at 7 V the part draws at most 0.1 uA, which is 0.7 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.
Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.
Why does the clamp voltage differ from the breakdown voltage?
Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.
How is the working voltage chosen?
Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.
Is the automotive suffix a different die?
It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd