Eaton STS521070U701AH ESD Suppressor 7 V 70 pF
Eaton STS521070U701AH ESD Suppressor 7 V 70 pF

Eaton STS521070U701AH ESD Suppressor 7 V 70 pF

Share
STS521070U701AH: 7 V standoff TVS diode array, 1-channel, 70 pF per line, SOD-523 (S52), AEC-Q101.
    • Product Details
    • Download

    Eaton STS521070U701AH ESD Suppressor 7 V 70 pF

    STS521070U701AH at a glance: TVS diode array ESD suppressor, 7 V standoff, 16 V clamp, 1 channel, 70 pF, 120 W.

    Key Specifications

    ParameterValue
    Orderable part numberSTS521070U701AH
    Standoff voltage (VRWM)7 V
    Breakdown voltage (min / typ / max)7.5 V / 8.5 V / 9.5 V
    Leakage current at VRWM0.1 uA max
    Peak pulse power, 8/20 us, per line120 W
    Clamping voltage at 1 A13 V
    Clamping voltage at 9 A16 V
    Junction capacitance at 1 MHz, per line70 pF typ / 85 pF max
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1281

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1281. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    What the Numbers Mean

    The STS series is a diode array in a three to eight pin package: one die per line, all of them sharing a common ground pin. The working voltage is set by the process, not by a resistor divider, so the part either sits above the bus level or it does not belong on that bus at all.

    At 9 A the clamp sits at 16 V, or 2.29 times the 7 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 120 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    70 pF per line is 2.3 ohms of reactance at 1 GHz and 22.7 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 7 V the part draws at most 0.1 uA, which is 0.7 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    The capacitance in the table is per line, measured at 1 MHz with zero bias. On a differential pair that capacitance sits across the pair and to ground, which is why the low-capacitance grades exist: the same clamp with a fraction of the loading.

    Where It Goes on the Board

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • ESD ratings are per IEC 61000-4-2 with the part as the first element the discharge meets. A connector shell or a mounting post that offers an easier path takes the strike instead, and the array never conducts.
    • Peak pulse power is an 8/20 microsecond figure per line. A longer waveform allows less current and a shorter one more; the derating curve in the data sheet converts between them and is the number to use when the surge is not the standard one.

    Frequently Asked Questions

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.

    Is the automotive suffix a different die?
    It is the same function qualified to AEC-Q101 with a wider tested temperature range and a moisture sensitivity level of 1 instead of 3. The electrical table is repeated per part number because the clamp and capacitance differ between them.