STS521360U221AH: 36 V standoff TVS diode array, 1-channel, 22 pF per line, SOD-523 (S52), AEC-Q101.
    • Product Details
    • Download

    Eaton STS521360U221AH TVS Diode 36 V 300 W

    STS521360U221AH at a glance: TVS diode array ESD suppressor, 36 V standoff, 60 V clamp, 1 channel, 22 pF, 300 W.

    Key Specifications

    ParameterValue
    Orderable part numberSTS521360U221AH
    Standoff voltage (VRWM)36 V
    Breakdown voltage (min / typ / max)40 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line300 W
    Clamping voltage at 1 A60 V
    Junction capacitance at 1 MHz, per line22 pF typ
    Channels1
    PolarityUnidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOD-523 (S52)
    MountingSurface mount
    Moisture sensitivity levelMSL 1
    Operating junction temperature-55 °C to +150 °C
    QualificationAEC-Q101
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1281

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data ELX1281. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    What the Numbers Mean

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    At 1 A the clamp sits at 60 V, or 1.67 times the 36 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 300 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    22 pF per line is 7.2 ohms of reactance at 1 GHz and 72.3 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.

    Standing at 36 V the part draws at most 1 uA, which is 36 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.

    Where It Goes on the Board

    Run the protected line through the pad rather than teeing off it. A stub of a few millimetres leaves a reflection that shows up as an eye closure on a fast pair and as a harmless glitch on a slow one, and the same layout serves both.

    • The clamping voltage is quoted at one pulse current. Halve the current and the clamp falls by roughly the dynamic resistance times the current, which is why a part chosen for a small surge looks better than its headline number.
    • Leakage is quoted at the rated voltage and at 25 °C. It roughly doubles every 10 °C, which matters on a rail that sits hot inside an enclosure.

    Frequently Asked Questions

    Why does the clamp voltage differ from the breakdown voltage?
    Breakdown is measured at 1 mA. The clamp is measured at the pulse current, which can be tens of amps, and the difference is the dynamic resistance of the junction multiplied by that current.

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    How is the working voltage chosen?
    Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.