Eaton STSP84150B601 ESD Suppressor 15 V 60 pF
Eaton STSP84150B601 ESD Suppressor 15 V 60 pF

Eaton STSP84150B601 ESD Suppressor 15 V 60 pF

Share
STSP84150B601: 15 V standoff TVS diode array, 4-channel, 60 pF per line, SOP-8 (SP8), commercial grade.
    • Product Details
    • Download

    Eaton STSP84150B601 ESD Suppressor 15 V 60 pF

    STSP84150B601 at a glance: TVS diode array ESD suppressor, 15 V standoff, 30 V clamp, 4 channels, 60 pF, 300 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSTSP84150B601
    Standoff voltage (VRWM)15 V
    Breakdown voltage (min / typ / max)16.5 V
    Leakage current at VRWM1 uA max
    Peak pulse power, 8/20 us, per line300 W
    Clamping voltage at 1 A24 V
    Clamping voltage at 12 A30 V
    Junction capacitance at 1 MHz, per line60 pF typ
    Channels4
    PolarityBidirectional
    ESD capability, IEC 61000-4-2+/-30 kV contact / +/-30 kV air
    PackageSOP-8 (SP8)
    MountingSurface mount
    Moisture sensitivity levelMSL 3
    Operating junction temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11160

    The outline drawing, pad geometry, derating curves and the pulse
    waveform are on the pages of Eaton Technical Data 11160. Values above are
    read directly from the electrical table for this part number, not from the family
    summary.

    The Figures Explained

    Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.

    At 12 A the clamp sits at 30 V, or 2.00 times the 15 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 300 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.

    60 pF per line is 2.7 ohms of reactance at 1 GHz and 26.5 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.

    Standing at 15 V the part draws at most 1 uA, which is 15 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.

    All 4 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.

    Array parts are chosen last, after the connector pinout is fixed. The pin that carries the discharge has to reach the array before it reaches the transceiver, and the ground pin of the array has to be the same copper the connector shell ties to.

    Placement in the Circuit

    Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.

    • The standoff voltage is a DC figure. A bus that idles at 5 V and swings to 12 V in a fault needs a part rated above 12 V, not above 5 V, or the array conducts on every fault and fails open.
    • The capacitance figure is at zero bias. At the working voltage the junction depletes and the value falls, so the loading on a live bus is lower than the table suggests.

    Frequently Asked Questions

    Can one package protect several lines?
    Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.

    How many of these parts survive repeated strikes?
    The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message