| Parameter | Value |
|---|---|
| Orderable part number | TL1211V2-R080-R |
| Primary inductance Lpri (terminals 3-4) | 80 nH ±10% |
| Secondary inductance Lsec (terminals 1-2) | 80 nH ±10% |
| FLL minimum at Isat1 | 57 nH |
| DCR primary @ +20 °C | 0.37 mOhm |
| DCR secondary @ +20 °C | 0.125 mOhm |
| Irms secondary (40 °C rise) | 75 A |
| Isat1 (20 % rolloff @ +25 °C) | 149 A |
| Isat2 (20 % rolloff @ +100 °C) | 127 A |
| Isat3 (20 % rolloff @ +125 °C) | 119 A |
| K-factor (Bp-p = K x L x dI x 10^-3) | 328 |
| Coupling coefficient Kps | 0.93 |
| Package | 12.0 x 6.0 mm, 11.0 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1157 |

Drawing reproduced from Eaton Technical Data ELX1157: outline views
with rated mm dimensions, pad layout and marking.
The coupling coefficient Kps is the figure that decides how much of a transient the loop can absorb. At 0.93 roughly nine tenths of the flux links both windings, so the secondary carries its share of the phase current automatically.
The secondary winding drops about 9.38 mV at its 75 A rating and dissipates roughly 0.703 W there. That is the loss the loop carries on top of the phase windings.
The K-factor turns the applied ripple into a flux swing through Bp-p = K x L x delta-I, with L taken at the operating point. That amplitude, not the DC current, is what the core-loss curve is read against.
With Kps at 0.93 the two windings share the flux almost completely; the fraction that does not link is what shows up as leakage inductance in the phase.
Within the TL1211V2 family this is value 2 of 8, in a range from 70 to 200 nH.
The TL and TLP families cover 70 nH to 200 nH of primary inductance in 9.6 x 6.4 mm, 10 x 6 mm and 12 x 6 mm bodies, with the secondary winding equal to the primary and a coupling coefficient between 0.91 and 0.95.
Why is the primary DCR larger than the secondary?
The primary carries the phase current through the full winding; the secondary is usually a single turn or a short winding because it only has to carry the difference current. The two are measured between different terminal pairs and are not interchangeable.
Can I use this part as an ordinary inductor?
Only if you leave the secondary open. With the secondary connected to the other phases the part is part of a loop and its effective inductance depends on what the rest of the loop is doing.
Which inductance do I use for the ripple calculation?
FLL, the full-load inductance, because that is the value at the current the converter actually runs at. OCL is the zero-bias figure and overstates the inductance at load; using it makes the ripple look smaller than it is.