| Parameter | Value |
|---|---|
| Orderable part number | TVSL02V07C006 |
| Standoff voltage (VRWM) | 7 V |
| Breakdown voltage (min / typ / max) | 7.5 V / 8.8 V / 10.5 V |
| Leakage current at VRWM | 1 uA max |
| Peak pulse power, 8/20 us, per line | 90 W |
| Clamping voltage at 1 A, TLP 100 ns (typ) | 9.2 V |
| Clamping voltage at 16 A, TLP 100 ns (typ) | 12.8 V |
| Junction capacitance at 1 MHz, per line | 8.5 pF typ / 10.3 pF max |
| Channels | 1 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-25 kV contact / +/-25 kV air |
| Package | 0201 (0603 metric) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1241 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data ELX1241. Values above are
read directly from the electrical table for this part number, not from the family
summary.
A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.
At 16 A the clamp sits at 12.8 V, or 1.83 times the 7 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 90 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
8.5 pF per line is 18.7 ohms of reactance at 1 GHz and 187 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.
Standing at 7 V the part draws at most 1 uA, which is 7 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.
Mount the array on the connector side of any series part, with the ground pin dropped straight into the connector ground plane. The trace from the pin to the array is the only path the discharge takes before the transceiver sees it, so its inductance is part of the clamp.
How is the working voltage chosen?
Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.
How many of these parts survive repeated strikes?
The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.
Can one package protect several lines?
Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.