| Parameter | Value |
|---|---|
| Orderable part number | TVSL02V12C008 |
| Standoff voltage (VRWM) | 12 V |
| Breakdown voltage (min / typ / max) | 15.5 V / 19 V / 22.5 V |
| Leakage current at VRWM | 1 uA max |
| Peak pulse power, 8/20 us, per line | 60 W |
| Clamping voltage at 1 A, TLP 100 ns (typ) | 15.8 V |
| Junction capacitance at 1 MHz, per line | 8.5 pF typ |
| Channels | 1 |
| Polarity | Bidirectional |
| ESD capability, IEC 61000-4-2 | +/-25 kV contact / +/-25 kV air |
| Package | 0201 (0603 metric) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 1 |
| Operating junction temperature | -55 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1241 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data ELX1241. Values above are
read directly from the electrical table for this part number, not from the family
summary.
Two numbers decide whether an array fits a port. The standoff voltage has to clear the highest steady level the line can hold, and the clamping voltage at the surge current has to stay under the absolute maximum of the transceiver behind it. Everything else on the data sheet is a consequence of those two.
At 1 A the clamp sits at 15.8 V, or 1.32 times the 12 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 60 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
8.5 pF per line is 18.7 ohms of reactance at 1 GHz and 187 ohms at 100 MHz. Small enough for a bus in the hundreds of kilohertz to a few megahertz, and measurable once the line rate reaches tens of megahertz.
Standing at 12 V the part draws at most 1 uA, which is 12 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.
Keep the return current under the signal. A discharge leaves through the ground pin, and if that current has to cross the board to find a plane it will couple into everything it passes on the way.
Does the array capacitance disturb the signal?
It loads the line as a capacitor to ground. At 1 pF the reactance is about 160 ohms at 1 GHz and 1.6 kilohms at 100 MHz, which is why the low-capacitance grades are used on high speed pairs and the higher grades on slow buses.
Can one package protect several lines?
Yes, that is what the channel count means. The lines share a common ground pin, so the return current of all channels flows through one connection and the clamps track each other during the event.
How many of these parts survive repeated strikes?
The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd