| Parameter | Value |
|---|---|
| Orderable part number | UP2B-1R0-R |
| Rated inductance | 1 uH ±20% |
| OCL (open circuit inductance) | 1 uH ±20% |
| Irms (40 °C rise, no core loss) | 9.3 A |
| Isat (peak, rolloff per data sheet) | 9.9 A |
| DCR typical @ +20 °C | 6.5 mOhm |
| Package | Four body sizes in this data sheet – see drawing |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data DS4308 |

Drawing reproduced from Eaton Technical Data DS4308: outline views
with rated mm dimensions, pad layout and marking.
A UNI-PAC drum core inductor is a wound coil on a ferrite drum with the winding brought out to two solder pads. There is no shield, so the field leaves the part along the drum axis. That is the trade: the most inductance per millimetre and per cent, paid for with a radiated field.
Copper loss at the 9.3 A rating is about 0.562 W with the typical DCR of 6.5 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 49 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
Within the UP2B family this is value 2 of 22, in a range from 0.47 to 1000 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
Why is DCR quoted in ohms on some of these data sheets?
Because the values are large: a 1000 uH part can be several ohms. The table on this page converts the figure to milliohm so it can be compared directly with the rest of the family.
How far does the field reach?
The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.
Is the saturation current defined at 20 % or 30 % rolloff?
It varies by data sheet. The rolloff point is stated in the note under the table of each document; the number on this page is the one printed for this part, not a normalised figure.