| Parameter | Value |
|---|---|
| Orderable part number | UP5-220-R |
| OCL (open circuit inductance) | 22 uH ±20% |
| Irms (40 °C rise, no core loss) | 3.5 A |
| Isat (peak, rolloff per data sheet) | 7 A |
| DCR typical @ +20 °C | 47 mOhm |
| SRF typical | 13 MHz |
| K-factor | 17 |
| Package | 18.54 x 15.24 mm, 7.11 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4409 |

Drawing reproduced from Eaton Technical Data 4409: outline views
with rated mm dimensions, pad layout and marking.
The construction is one piece – drum, winding, terminations – which is why the family reaches 1000 uH in a package a few millimetres across while staying a surface-mount part. Values below 1 uH and above 500 uH sit in the same body size.
Copper loss at the 3.5 A rating is about 0.576 W with the typical DCR of 47 mOhm. Ripple current adds to that through the AC resistance.
The core holds about 539 uJ at the saturation point, which is the energy available to bridge a load step before the inductance collapses.
Within the UP5 family this is value 8 of 18, in a range from 1 to 1000 uH.
The UP family runs from 0.47 uH to 1000 uH in bodies from 6.6 x 4.45 mm up to 18.54 x 15.24 mm, all unshielded drum core, all with the saturation and thermal ratings quoted separately.
Why is DCR quoted in ohms on some of these data sheets?
Because the values are large: a 1000 uH part can be several ohms. The table on this page converts the figure to milliohm so it can be compared directly with the rest of the family.
Why does the inductance fall so gradually with current?
The drum has a distributed air gap along its length, so the core saturates progressively instead of all at once. That soft knee is why drum core parts stay usable slightly beyond the quoted saturation point.
How far does the field reach?
The drum is open at both ends, so the field leaves along the axis and returns around the body. Keep traces and vias out from under the part and keep sensitive nodes off the axis. A shielded part is the answer when that is not possible.