Eaton VP1-0076-R Versa-Pac Configurable Inductor
Eaton VP1-0076-R Versa-Pac Configurable Inductor

Eaton VP1-0076-R Versa-Pac Configurable Inductor

Share
VP1-0076-R: configurable six-winding inductor transformer, 4.9 uH.
    • Product Details
    • Download

    Eaton VP1-0076-R Versa-Pac Configurable Inductor

    VP1-0076-R at a glance: configurable six-winding inductor transformer, 4.9 uH.

    Ratings at a Glance

    ParameterValue
    Orderable part numberVP1-0076-R
    Inductance, base winding4.9 uH
    Isat base1.06 A
    Irms base0.85 A
    R base maximum145 mOhm
    Volt-time21.8 V-us
    Peak energy1.92 uJ
    Leakage inductance0.096 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    The ratings on this page are for the base winding with all others open or paralleled as noted. Any other connection changes the effective inductance and current, and the table of configurations is the place to look.

    Within the VP1 family this is item 2 of 4 in the Eaton catalogue.

    Positioning in the Range

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    Are the ratings per winding or total?
    The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message