| Parameter | Value |
|---|---|
| Orderable part number | VP2-0216-R |
| Inductance, base winding | 10.6 uH |
| Isat base | 0.76 A |
| Irms base | 1.26 A |
| R base maximum | 90 mOhm |
| Volt-time | 33.7 V-us |
| Peak energy | 2.11 uJ |
| Leakage inductance | 0.083 uH |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4301 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data 4301; the package line above gives the body size where
the data sheet states it.
Configurable magnetics trade a little efficiency for flexibility: more windings in the same window means thinner wire, so the DCR is higher than a dedicated part of the same inductance.
Within the VP2 family this is item 4 of 4 in the Eaton catalogue.
The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.
Are the ratings per winding or total?
The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.
Why is the DCR higher than a dedicated inductor?
Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.
Can it be used as a transformer?
Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.