Eaton VP3-0138-R Versa-Pac Configurable Inductor
Eaton VP3-0138-R Versa-Pac Configurable Inductor

Eaton VP3-0138-R Versa-Pac Configurable Inductor

Share
VP3-0138-R: configurable six-winding inductor transformer, 11.2 uH.
    • Product Details
    • Download

    Eaton VP3-0138-R Versa-Pac Configurable Inductor

    VP3-0138-R at a glance: configurable six-winding inductor transformer, 11.2 uH.

    Specification Table

    ParameterValue
    Orderable part numberVP3-0138-R
    Inductance, base winding11.2 uH
    Isat base0.59 A
    Irms base1.47 A
    R base maximum61 mOhm
    Volt-time27.7 V-us
    Peak energy1.36 uJ
    Leakage inductance0.058 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    Versa-Pac parts are built for prototyping and for designs that need several different magnetics on one board: the same footprint can be a 10 uH inductor at full current or a 1:1 transformer, depending on how the six windings are wired.

    Within the VP3 family this is item 2 of 2 in the Eaton catalogue.

    What This Family Is For

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    Are the ratings per winding or total?
    The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.

    Why is the DCR higher than a dedicated inductor?
    Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.

    Are the ratings per winding or total?
    The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.