Eaton VPH1-0059-R Six-Winding Inductor 8.5 uH
Eaton VPH1-0059-R Six-Winding Inductor 8.5 uH

Eaton VPH1-0059-R Six-Winding Inductor 8.5 uH

Share
VPH1-0059-R: configurable six-winding inductor transformer, 8.5 uH.
    • Product Details
    • Download

    Eaton VPH1-0059-R Six-Winding Inductor 8.5 uH

    VPH1-0059-R at a glance: configurable six-winding inductor transformer, 8.5 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberVPH1-0059-R
    Inductance, base winding8.5 uH
    Isat base0.92 A
    Irms base0.55 A
    R base maximum344 mOhm
    Volt-time32.9 V-us
    Peak energy2.48 uJ
    Leakage inductance0.212 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A six-winding configurable inductor: the windings can be paralleled for current, series-connected for inductance, or used as a multi-winding transformer. One part covers a wide design space, which is why the data sheet gives base ratings and a table of configurations rather than a single row.

    Within the VPH1 family this is item 1 of 3 in the Eaton catalogue.

    Positioning in the Range

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Are the ratings per winding or total?
    The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.

    Why is the DCR higher than a dedicated inductor?
    Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.