Eaton VPH5-0053-R Configurable Power Inductor
Eaton VPH5-0053-R Configurable Power Inductor

Eaton VPH5-0053-R Configurable Power Inductor

Share
VPH5-0053-R: configurable six-winding inductor transformer, 7.63 uH.
    • Product Details
    • Download

    Eaton VPH5-0053-R Configurable Power Inductor

    VPH5-0053-R at a glance: configurable six-winding inductor transformer, 7.63 uH.

    Key Specifications

    ParameterValue
    Orderable part numberVPH5-0053-R
    Inductance, base winding7.63 uH
    Isat base3.07 A
    Irms base1.7 A
    R base maximum71.1 mOhm
    Volt-time98.4 V-us
    Peak energy25.1 uJ
    Leakage inductance0.235 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    Configurable magnetics trade a little efficiency for flexibility: more windings in the same window means thinner wire, so the DCR is higher than a dedicated part of the same inductance.

    Within the VPH5 family this is item 1 of 4 in the Eaton catalogue.

    Series Positioning

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    Why is the DCR higher than a dedicated inductor?
    Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message