Eaton WCL2520-390-R 39 uH Wire Wound Chip Inductor
Eaton WCL2520-390-R 39 uH Wire Wound Chip Inductor

Eaton WCL2520-390-R 39 uH Wire Wound Chip Inductor

Share
WCL2520-390-R: wire wound chip inductor, 39 uH ±5%, Q 10 at 2.52 MHz, 80 mA rated, DCR 5000 mOhm.
    • Product Details
    • Download

    Eaton WCL2520-390-R 39 uH Wire Wound Chip Inductor

    WCL2520-390-R at a glance: wire wound chip inductor, 39 uH ±5%, Q 10 at 2.52 MHz, 80 mA rated, DCR 5000 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCL2520-390-R
    OCL39 uH ±5%
    Q minimum @ test frequency10 @ 2.52 MHz
    SRF minimum7 MHz
    DCR maximum @ +25 °C5000 mOhm
    Rated current (20 °C rise)80 mA
    OCL test frequency2.52 MHz
    OCL test voltage500 mV
    Package2.92 x 2.79 mm, 2.10 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10930

    Mechanical Drawing

    WCL2520-390-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10930: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 80 mA rating the winding drops about 400 mV and dissipates 32 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 10 at 2.52 MHz with self-resonance at 7 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL2520 family this is value 25 of 33, in a range from 0.12 to 220 uH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.