| Parameter | Value |
|---|---|
| Orderable part number | WCL2520-R680-R |
| OCL | 0.68 uH ±5% |
| Q minimum @ test frequency | 12 @ 25.2 MHz |
| SRF minimum | 330 MHz |
| DCR maximum @ +25 °C | 450 mOhm |
| Rated current (20 °C rise) | 600 mA |
| OCL test frequency | 25.2 MHz |
| OCL test voltage | 500 mV |
| Package | 2.92 x 2.79 mm, 2.10 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10930 |

Drawing reproduced from Eaton Technical Data 10930: outline views
with rated mm dimensions, pad layout and marking.
The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.
At the 600 mA rating the winding drops about 270 mV and dissipates 162 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 12 at 25.2 MHz with self-resonance at 330 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCL2520 family this is value 4 of 33, in a range from 0.12 to 220 uH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
What happens above the self-resonant frequency?
The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.
Why choose wire wound over multilayer?
Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd