Eaton WCL3225-271-R 270 uH Chip Inductor, Q 8
Eaton WCL3225-271-R 270 uH Chip Inductor, Q 8

Eaton WCL3225-271-R 270 uH Chip Inductor, Q 8

Share
WCL3225-271-R: wire wound chip inductor, 270 uH ±5%, Q 8 at 0.796 MHz, 60 mA rated, DCR 18000 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-271-R 270 uH Chip Inductor, Q 8

    WCL3225-271-R at a glance: wire wound chip inductor, 270 uH ±5%, Q 8 at 0.796 MHz, 60 mA rated, DCR 18000 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCL3225-271-R
    OCL270 uH ±5%
    Q minimum @ test frequency8 @ 0.796 MHz
    SRF minimum2.5 MHz
    DCR maximum @ +25 °C18000 mOhm
    Rated current (20 °C rise)60 mA
    OCL test frequency0.796 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Mechanical Dimensions & Pad Layout

    WCL3225-271-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 60 mA rating the winding drops about 1080 mV and dissipates 64.8 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 8 at 0.796 MHz with self-resonance at 2.5 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 35 of 39, in a range from 0.12 to 560 uH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.