| Parameter | Value |
|---|---|
| Orderable part number | WCL3225-331-R |
| OCL | 330 uH ±5% |
| Q minimum @ test frequency | 8 @ 0.796 MHz |
| SRF minimum | 2.3 MHz |
| DCR maximum @ +25 °C | 19000 mOhm |
| Rated current (20 °C rise) | 55 mA |
| OCL test frequency | 0.796 MHz |
| OCL test voltage | 500 mV |
| Package | 3.5 x 2.9 mm, 2.25 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10931 |

Drawing reproduced from Eaton Technical Data 10931: outline views
with rated mm dimensions, pad layout and marking.
The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.
At the 55 mA rating the winding drops about 1045 mV and dissipates 57.5 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 8 at 0.796 MHz with self-resonance at 2.3 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCL3225 family this is value 36 of 39, in a range from 0.12 to 560 uH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.
Why choose wire wound over multilayer?
Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.
Is the automotive version electrically different?
The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.