Eaton WCL3225-3R9-R 3.9 uH RF Chip Inductor, SRF 75 MHz
Eaton WCL3225-3R9-R 3.9 uH RF Chip Inductor, SRF 75 MHz

Eaton WCL3225-3R9-R 3.9 uH RF Chip Inductor, SRF 75 MHz

Share
WCL3225-3R9-R: wire wound chip inductor, 3.9 uH ±5%, Q 12 at 7.96 MHz, 360 mA rated, DCR 1200 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-3R9-R 3.9 uH RF Chip Inductor, SRF 75 MHz

    WCL3225-3R9-R at a glance: wire wound chip inductor, 3.9 uH ±5%, Q 12 at 7.96 MHz, 360 mA rated, DCR 1200 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCL3225-3R9-R
    OCL3.9 uH ±5%
    Q minimum @ test frequency12 @ 7.96 MHz
    SRF minimum75 MHz
    DCR maximum @ +25 °C1200 mOhm
    Rated current (20 °C rise)360 mA
    OCL test frequency7.96 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Outline Drawing

    WCL3225-3R9-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 360 mA rating the winding drops about 432 mV and dissipates 156 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 12 at 7.96 MHz with self-resonance at 75 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 13 of 39, in a range from 0.12 to 560 uH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.