| Parameter | Value |
|---|---|
| Orderable part number | WCLA1005V1-1R8-R |
| OCL | 1.8 nH ±10% |
| Q minimum @ test frequency | 16 @ 250 MHz |
| SRF minimum | 6000 MHz |
| DCR maximum @ +25 °C | 70 mOhm |
| Rated current (20 °C rise) | 1040 mA |
| OCL test frequency | 250 MHz |
| OCL test voltage | 500 mV |
| Package | 1.19 x 0.66 mm, 0.60 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10981 |

Drawing reproduced from Eaton Technical Data 10981: outline views
with rated mm dimensions, pad layout and marking.
Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.
At the 1040 mA rating the winding drops about 72.8 mV and dissipates 75.7 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 16 at 250 MHz with self-resonance at 6000 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCLA1005V1 family this is value 3 of 52, in a range from 1 to 120 nH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
What happens above the self-resonant frequency?
The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
Shenzhen Gaorunxin Technology Co., Ltd