Eaton WCLA1005V1-430-R 43 nH Chip Inductor, Q 25
Eaton WCLA1005V1-430-R 43 nH Chip Inductor, Q 25

Eaton WCLA1005V1-430-R 43 nH Chip Inductor, Q 25

Share
WCLA1005V1-430-R: wire wound chip inductor, 43 nH ±5%, Q 25 at 250 MHz, 100 mA rated, DCR 810 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-430-R 43 nH Chip Inductor, Q 25

    WCLA1005V1-430-R at a glance: wire wound chip inductor, 43 nH ±5%, Q 25 at 250 MHz, 100 mA rated, DCR 810 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberWCLA1005V1-430-R
    OCL43 nH ±5%
    Q minimum @ test frequency25 @ 250 MHz
    SRF minimum2030 MHz
    DCR maximum @ +25 °C810 mOhm
    Rated current (20 °C rise)100 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Mechanical Dimensions & Pad Layout

    WCLA1005V1-430-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.

    At the 100 mA rating the winding drops about 81 mV and dissipates 8.1 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 25 at 250 MHz with self-resonance at 2030 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 43 of 52, in a range from 1 to 120 nH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.