Eaton WCLA1005V1-4R7-R 4.7 nH Chip Inductor, Q 18
Eaton WCLA1005V1-4R7-R 4.7 nH Chip Inductor, Q 18

Eaton WCLA1005V1-4R7-R 4.7 nH Chip Inductor, Q 18

Share
WCLA1005V1-4R7-R: wire wound chip inductor, 4.7 nH ±5%, Q 18 at 250 MHz, 640 mA rated, DCR 200 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-4R7-R 4.7 nH Chip Inductor, Q 18

    WCLA1005V1-4R7-R at a glance: wire wound chip inductor, 4.7 nH ±5%, Q 18 at 250 MHz, 640 mA rated, DCR 200 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberWCLA1005V1-4R7-R
    OCL4.7 nH ±5%
    Q minimum @ test frequency18 @ 250 MHz
    SRF minimum4500 MHz
    DCR maximum @ +25 °C200 mOhm
    Rated current (20 °C rise)640 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Outline Drawing

    WCLA1005V1-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.

    At the 640 mA rating the winding drops about 128 mV and dissipates 81.9 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 18 at 250 MHz with self-resonance at 4500 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 15 of 52, in a range from 1 to 120 nH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.