Eaton WCLA1005V1-7R5-R 7.5 nH Wire Wound Chip Inductor
Eaton WCLA1005V1-7R5-R 7.5 nH Wire Wound Chip Inductor

Eaton WCLA1005V1-7R5-R 7.5 nH Wire Wound Chip Inductor

Share
WCLA1005V1-7R5-R: wire wound chip inductor, 7.5 nH ±5%, Q 23 at 250 MHz, 680 mA rated, DCR 100 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-7R5-R 7.5 nH Wire Wound Chip Inductor

    WCLA1005V1-7R5-R at a glance: wire wound chip inductor, 7.5 nH ±5%, Q 23 at 250 MHz, 680 mA rated, DCR 100 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberWCLA1005V1-7R5-R
    OCL7.5 nH ±5%
    Q minimum @ test frequency23 @ 250 MHz
    SRF minimum4800 MHz
    DCR maximum @ +25 °C100 mOhm
    Rated current (20 °C rise)680 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Outline Drawing

    WCLA1005V1-7R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 680 mA rating the winding drops about 68 mV and dissipates 46.2 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 23 at 250 MHz with self-resonance at 4800 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 20 of 52, in a range from 1 to 120 nH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.