Eaton WCLA2012V1-120-R 12 nH Inductor, 600 mA Rated
Eaton WCLA2012V1-120-R 12 nH Inductor, 600 mA Rated

Eaton WCLA2012V1-120-R 12 nH Inductor, 600 mA Rated

Share
WCLA2012V1-120-R: wire wound chip inductor, 12 nH ±5%, Q 50 at 500 MHz, 600 mA rated, DCR 150 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-120-R 12 nH Inductor, 600 mA Rated

    WCLA2012V1-120-R at a glance: wire wound chip inductor, 12 nH ±5%, Q 50 at 500 MHz, 600 mA rated, DCR 150 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCLA2012V1-120-R
    OCL12 nH ±5%
    Q minimum @ test frequency50 @ 500 MHz
    SRF minimum4000 MHz
    DCR maximum @ +25 °C150 mOhm
    Rated current (20 °C rise)600 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Mechanical Dimensions & Pad Layout

    WCLA2012V1-120-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    This is a wire wound chip inductor for RF and small-signal circuits: tight tolerance, defined Q, and a rated current that is set by a 20 °C self-temperature rise rather than by saturation.

    At the 600 mA rating the winding drops about 90 mV and dissipates 54 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 50 at 500 MHz with self-resonance at 4000 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 9 of 36, in a range from 2.2 to 2200 nH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd