| Parameter | Value |
|---|---|
| Orderable part number | WCLA2012V1-181-R |
| OCL | 180 nH ±5% |
| Q minimum @ test frequency | 45 @ 250 MHz |
| SRF minimum | 870 MHz |
| DCR maximum @ +25 °C | 640 mOhm |
| Rated current (20 °C rise) | 400 mA |
| OCL test frequency | 100 MHz |
| OCL test voltage | 500 mV |
| Package | 2.30 x 1.70 mm, 1.52 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10983 |

Drawing reproduced from Eaton Technical Data 10983: outline views
with rated mm dimensions, pad layout and marking.
A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.
At the 400 mA rating the winding drops about 256 mV and dissipates 102 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 45 at 250 MHz with self-resonance at 870 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCLA2012V1 family this is value 23 of 36, in a range from 2.2 to 2200 nH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
Is the automotive version electrically different?
The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.
Is the automotive version electrically different?
The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.