Eaton WCLA2012V1-3R3-R 3.3 nH Wire Wound Chip Inductor
Eaton WCLA2012V1-3R3-R 3.3 nH Wire Wound Chip Inductor

Eaton WCLA2012V1-3R3-R 3.3 nH Wire Wound Chip Inductor

Share
WCLA2012V1-3R3-R: wire wound chip inductor, 3.3 nH ±10%, Q 35 at 1500 MHz, 600 mA rated, DCR 90 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-3R3-R 3.3 nH Wire Wound Chip Inductor

    WCLA2012V1-3R3-R at a glance: wire wound chip inductor, 3.3 nH ±10%, Q 35 at 1500 MHz, 600 mA rated, DCR 90 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberWCLA2012V1-3R3-R
    OCL3.3 nH ±10%
    Q minimum @ test frequency35 @ 1500 MHz
    SRF minimum7900 MHz
    DCR maximum @ +25 °C90 mOhm
    Rated current (20 °C rise)600 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Outline Drawing

    WCLA2012V1-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 600 mA rating the winding drops about 54 mV and dissipates 32.4 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 35 at 1500 MHz with self-resonance at 7900 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 3 of 36, in a range from 2.2 to 2200 nH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.