Eaton WCLA2012V1-561-R 560 nH Inductor, 230 mA Rated
Eaton WCLA2012V1-561-R 560 nH Inductor, 230 mA Rated

Eaton WCLA2012V1-561-R 560 nH Inductor, 230 mA Rated

Share
WCLA2012V1-561-R: wire wound chip inductor, 560 nH ±5%, Q 23 at 50 MHz, 230 mA rated, DCR 1900 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-561-R 560 nH Inductor, 230 mA Rated

    WCLA2012V1-561-R at a glance: wire wound chip inductor, 560 nH ±5%, Q 23 at 50 MHz, 230 mA rated, DCR 1900 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberWCLA2012V1-561-R
    OCL560 nH ±5%
    Q minimum @ test frequency23 @ 50 MHz
    SRF minimum340 MHz
    DCR maximum @ +25 °C1900 mOhm
    Rated current (20 °C rise)230 mA
    OCL test frequency25 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Outline Drawing

    WCLA2012V1-561-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 230 mA rating the winding drops about 437 mV and dissipates 101 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 23 at 50 MHz with self-resonance at 340 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 29 of 36, in a range from 2.2 to 2200 nH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products