| Parameter | Value |
|---|---|
| Orderable part number | WCLA2012V1-680-R |
| OCL | 68 nH ±5% |
| Q minimum @ test frequency | 55 @ 500 MHz |
| SRF minimum | 1450 MHz |
| DCR maximum @ +25 °C | 380 mOhm |
| Rated current (20 °C rise) | 500 mA |
| OCL test frequency | 200 MHz |
| OCL test voltage | 500 mV |
| Package | 2.30 x 1.70 mm, 1.52 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10983 |

Drawing reproduced from Eaton Technical Data 10983: outline views
with rated mm dimensions, pad layout and marking.
The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.
At the 500 mA rating the winding drops about 190 mV and dissipates 95 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 55 at 500 MHz with self-resonance at 1450 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCLA2012V1 family this is value 18 of 36, in a range from 2.2 to 2200 nH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
Is the automotive version electrically different?
The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.
Why choose wire wound over multilayer?
Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.
What happens above the self-resonant frequency?
The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.