Eaton WCLA2012V1-680-R 68 nH Chip Inductor, Q 55
Eaton WCLA2012V1-680-R 68 nH Chip Inductor, Q 55

Eaton WCLA2012V1-680-R 68 nH Chip Inductor, Q 55

Share
WCLA2012V1-680-R: wire wound chip inductor, 68 nH ±5%, Q 55 at 500 MHz, 500 mA rated, DCR 380 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-680-R 68 nH Chip Inductor, Q 55

    WCLA2012V1-680-R at a glance: wire wound chip inductor, 68 nH ±5%, Q 55 at 500 MHz, 500 mA rated, DCR 380 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberWCLA2012V1-680-R
    OCL68 nH ±5%
    Q minimum @ test frequency55 @ 500 MHz
    SRF minimum1450 MHz
    DCR maximum @ +25 °C380 mOhm
    Rated current (20 °C rise)500 mA
    OCL test frequency200 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Outline Drawing

    WCLA2012V1-680-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 500 mA rating the winding drops about 190 mV and dissipates 95 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 55 at 500 MHz with self-resonance at 1450 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 18 of 36, in a range from 2.2 to 2200 nH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.