Eaton WCLA2520V1-330-R 33 uH Wire Wound Chip Inductor
Eaton WCLA2520V1-330-R 33 uH Wire Wound Chip Inductor

Eaton WCLA2520V1-330-R 33 uH Wire Wound Chip Inductor

Share
WCLA2520V1-330-R: wire wound chip inductor, 33 uH ±10%, Q 12 at 2.52 MHz, 236 mA rated, DCR 2470 mOhm.
    • Product Details
    • Download

    Eaton WCLA2520V1-330-R 33 uH Wire Wound Chip Inductor

    WCLA2520V1-330-R at a glance: wire wound chip inductor, 33 uH ±10%, Q 12 at 2.52 MHz, 236 mA rated, DCR 2470 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCLA2520V1-330-R
    OCL33 uH ±10%
    Q minimum @ test frequency12 @ 2.52 MHz
    SRF minimum15 MHz
    DCR maximum @ +25 °C2470 mOhm
    Rated current (20 °C rise)236 mA
    OCL test frequency2.52 MHz
    OCL test voltage500 mV
    Package2.90 x 2.50 mm, 2.10 mm high
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1152

    Mechanical Drawing

    WCLA2520V1-330-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1152: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.

    At the 236 mA rating the winding drops about 583 mV and dissipates 138 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 12 at 2.52 MHz with self-resonance at 15 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2520V1 family this is value 12 of 13, in a range from 0.22 to 47 uH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.