| Parameter | Value |
|---|---|
| Orderable part number | WCLA2520V1-330-R |
| OCL | 33 uH ±10% |
| Q minimum @ test frequency | 12 @ 2.52 MHz |
| SRF minimum | 15 MHz |
| DCR maximum @ +25 °C | 2470 mOhm |
| Rated current (20 °C rise) | 236 mA |
| OCL test frequency | 2.52 MHz |
| OCL test voltage | 500 mV |
| Package | 2.90 x 2.50 mm, 2.10 mm high |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1152 |

Drawing reproduced from Eaton Technical Data ELX1152: outline views
with rated mm dimensions, pad layout and marking.
Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.
At the 236 mA rating the winding drops about 583 mV and dissipates 138 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 12 at 2.52 MHz with self-resonance at 15 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCLA2520V1 family this is value 12 of 13, in a range from 0.22 to 47 uH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd