Eaton WCLA2520V1-3R3-R 3.3 uH RF Chip Inductor, SRF 48 MHz
Eaton WCLA2520V1-3R3-R 3.3 uH RF Chip Inductor, SRF 48 MHz

Eaton WCLA2520V1-3R3-R 3.3 uH RF Chip Inductor, SRF 48 MHz

Share
WCLA2520V1-3R3-R: wire wound chip inductor, 3.3 uH ±10%, Q 12 at 7.96 MHz, 715 mA rated, DCR 260 mOhm.
    • Product Details
    • Download

    Eaton WCLA2520V1-3R3-R 3.3 uH RF Chip Inductor, SRF 48 MHz

    WCLA2520V1-3R3-R at a glance: wire wound chip inductor, 3.3 uH ±10%, Q 12 at 7.96 MHz, 715 mA rated, DCR 260 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCLA2520V1-3R3-R
    OCL3.3 uH ±10%
    Q minimum @ test frequency12 @ 7.96 MHz
    SRF minimum48 MHz
    DCR maximum @ +25 °C260 mOhm
    Rated current (20 °C rise)715 mA
    OCL test frequency7.96 MHz
    OCL test voltage500 mV
    Package2.90 x 2.50 mm, 2.10 mm high
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1152

    Mechanical Dimensions & Pad Layout

    WCLA2520V1-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1152: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 715 mA rating the winding drops about 186 mV and dissipates 133 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 12 at 7.96 MHz with self-resonance at 48 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2520V1 family this is value 5 of 13, in a range from 0.22 to 47 uH.

    Positioning in the Range

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.