KLU-1500 Eaton Bussmann 600VAC 1500A Class L Fuse
KLU-1500 Eaton Bussmann 600VAC 1500A Class L Fuse

KLU-1500 Eaton Bussmann 600VAC 1500A Class L Fuse

Share
Eaton Bussmann KLU-1500, 600VAC, 1500A class l fuse, 200kA interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 1500A
    • Rated voltage 600VAC
    • Interrupting rating 200kA
    • Class L class

    The Eaton Bussmann KLU-1500 is a class l fuse rated 600VAC at 1500A and with a 200kA interrupting rating. It is used for service and feeder protection in large distribution equipment. 1500A 600VAC, Current Limiting, Time Delay, Class L Fuse, Eaton Bussmann Series.

    Key Specifications

    Product NameEaton Bussmann KLU Limitron Current Limiting Class L Fuse
    BrandCooper Bussmann
    Catalog NumberKLU-1500
    Rated Amperage1500A
    Rated Voltage600VAC
    Product Length10.75 in
    Product Diameter3 in
    Product Weight5.95 lb
    ClassClass L
    Voltage TypeAC
    Fuse SizeLimitron
    SPQ1
    Breaking Capacity200kA
    3D Model / CADContact us
    Agency InformationUL Listed, Std 248-10, Class L, Guide JDDZ, File E4273, CSA Certified, CSA Class 1422-02, File 53787, RoHS compliant, CE

    Same-Series Models

    ModelCurrentVoltageClass
    KLU-601601A600VACClass L
    KLU-650650A600VACClass L
    KLU-700700A600VACClass L
    KLU-800800A600VACClass L
    KLU-800-Fuse800A1600VClass L
    KLU-10001000A600VACClass L
    KLU-12001200A600VACClass L
    KLU-15001500A600VACClass L
    KLU-18001800A600VACClass L
    KLU-20002000A600VACClass L
    KLU-25002500A600VACClass L
    KLU-30003000A600VACClass L
    KLU-40004000A600VClass L Fuse
    KLU-16004000A600VACClass L

    14 models in the KLU family, sorted by rated current.

    Applications

    Service and feeder protection in large distribution equipment.

    Common Questions

    What is the KLU-1500 rated for?

    It is rated 600VAC at 1500A. The interrupting rating is 200kA. It is a Class L fuse.

    What class is this fuse?

    Class L.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number KLU-1500; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for KLU-1500. Verify ratings against the current datasheet before ordering.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message