KLU-4000 Eaton Bussmann 600V 4000A Class L Fuse
KLU-4000 Eaton Bussmann 600V 4000A Class L Fuse

KLU-4000 Eaton Bussmann 600V 4000A Class L Fuse

Share
Eaton Bussmann KLU-4000, 600V, 4000A class l fuse, 200kA interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 4000A
    • Rated voltage 600V
    • Interrupting rating 200kA
    • Class L Fuse class

    The Eaton Bussmann KLU-4000 is a class l fuse rated 600V at 4000A and with a 200kA interrupting rating. It is used for service and feeder protection in large distribution equipment. 4000A 600VAC Time-delay Class L fuse,Cooper Bussmann Limitron Fuse.

    Key Specifications

    Product NameEaton Bussmann series KLU Class L Time Delay Fuse
    Catalog NumberKLU-4000
    Rated Amperage4000A
    Rated Voltage600V
    Product Height5.75 in
    Product Length10.75 in
    Product Width5.75 in
    Product Weight22.15 lb
    ClassClass L Fuse
    Voltage TypeAC
    Mounting MethodBolt
    Breaking Capacity200kA
    3D Model / CADContact
    ApplicationLarge distribution switchboards • Power panelboards • Large machinery disconnects
    Agency InformationUL Listed, Std 248-15, Class T, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787, RoHS compliant, CE

    Same-Series Models

    ModelCurrentVoltageClass
    KLU-601601A600VACClass L
    KLU-650650A600VACClass L
    KLU-700700A600VACClass L
    KLU-800800A600VACClass L
    KLU-800-Fuse800A1600VClass L
    KLU-10001000A600VACClass L
    KLU-12001200A600VACClass L
    KLU-15001500A600VACClass L
    KLU-18001800A600VACClass L
    KLU-20002000A600VACClass L
    KLU-25002500A600VACClass L
    KLU-30003000A600VACClass L
    KLU-40004000A600VClass L Fuse
    KLU-16004000A600VACClass L

    14 models in the KLU family, sorted by rated current.

    Applications

    • Large distribution switchboards • Power panelboards • Large machinery disconnects.

    Service and feeder protection in large distribution equipment.

    Common Questions

    What is the KLU-4000 rated for?

    It is rated 600V at 4000A. The interrupting rating is 200kA. It is a Class L Fuse fuse.

    What class is this fuse?

    Class L Fuse.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number KLU-4000; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for KLU-4000. Verify ratings against the current datasheet before ordering.