The Eaton Bussmann KLU-4000 is a class l fuse rated 600V at 4000A and with a 200kA interrupting rating. It is used for service and feeder protection in large distribution equipment. 4000A 600VAC Time-delay Class L fuse,Cooper Bussmann Limitron Fuse.
| Product Name | Eaton Bussmann series KLU Class L Time Delay Fuse |
| Catalog Number | KLU-4000 |
| Rated Amperage | 4000A |
| Rated Voltage | 600V |
| Product Height | 5.75 in |
| Product Length | 10.75 in |
| Product Width | 5.75 in |
| Product Weight | 22.15 lb |
| Class | Class L Fuse |
| Voltage Type | AC |
| Mounting Method | Bolt |
| Breaking Capacity | 200kA |
| 3D Model / CAD | Contact |
| Application | Large distribution switchboards • Power panelboards • Large machinery disconnects |
| Agency Information | UL Listed, Std 248-15, Class T, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787, RoHS compliant, CE |
| Model | Current | Voltage | Class |
|---|---|---|---|
| KLU-601 | 601A | 600VAC | Class L |
| KLU-650 | 650A | 600VAC | Class L |
| KLU-700 | 700A | 600VAC | Class L |
| KLU-800 | 800A | 600VAC | Class L |
| KLU-800-Fuse | 800A | 1600V | Class L |
| KLU-1000 | 1000A | 600VAC | Class L |
| KLU-1200 | 1200A | 600VAC | Class L |
| KLU-1500 | 1500A | 600VAC | Class L |
| KLU-1800 | 1800A | 600VAC | Class L |
| KLU-2000 | 2000A | 600VAC | Class L |
| KLU-2500 | 2500A | 600VAC | Class L |
| KLU-3000 | 3000A | 600VAC | Class L |
| KLU-4000 | 4000A | 600V | Class L Fuse |
| KLU-1600 | 4000A | 600VAC | Class L |
14 models in the KLU family, sorted by rated current.
• Large distribution switchboards • Power panelboards • Large machinery disconnects.
Service and feeder protection in large distribution equipment.
What is the KLU-4000 rated for?
It is rated 600V at 4000A. The interrupting rating is 200kA. It is a Class L Fuse fuse.
What class is this fuse?
Class L Fuse.
Can I replace it with a different class?
No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.
What does the interrupting rating mean?
It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.
How do I verify the part number?
Order by the full catalog number KLU-4000; suffixes change the terminal, voltage or package.
Where can I find the datasheet?
The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.
Source: manufacturer catalog page for KLU-4000. Verify ratings against the current datasheet before ordering.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd