Littelfuse 0464001.DR 1 A 464 fast-acting SMD Fuse
Littelfuse 0464001.DR 1 A 464 fast-acting SMD Fuse

Littelfuse 0464001.DR 1 A 464 fast-acting SMD Fuse

Share
pLittelfuse 0464001.DR — 1 A, 250 V, fast-acting SMD fuse, 100 A @ 250 VAC interrupting./p
    • Product Details
    • Download

    Littelfuse 0464001.DR 1 A 464 fast-acting SMD Fuse

    Built by Littelfuse, the 0464001.DR carries 1 A, rated 250 VAC, uses a fast-acting element.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / 464 Series
    Part number0464001.DR
    Fuse characteristicfast-acting
    Rated current1 A
    Voltage rating250 VAC
    Interrupting rating100 A @ 250 VAC
    Nominal cold resistance0.0762 Ω
    Nominal melting I²t0.51 A²s
    Package12.1 × 4.5 mm NANO2 UMF
    Operating temperature-55 °C to +125 °C
    Agency / environmentalIEC 60127-4 UMF, PSE/UL approvals by rating, RoHS compliant and halogen-free

    Selection Notes

    • Interrupting capability is 100 A @ 250 VAC — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Working voltage must stay at or below 250 VAC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 1 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV
    • lighting

    Part Number and Packing

    Order code 0464001.DR from Littelfuse, supplied in 12.1 × 4.5 mm NANO2 UMF. Confirm the exact suffix before release.

    Q&A

    What are the ratings of the 0464001.DR?

    1 A continuous at 250 VAC, interrupting rating 100 A @ 250 VAC.

    Is the 0464001.DR fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the 0464001.DR be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A @ 250 VAC. Choose a part whose breaking capacity exceeds the prospective fault current.