The Eaton Bussmann LPN-RK-40SP is a class rk1 fuse rated 250VAC at 40A and with a 300kA RMS Sym. • 100kA DC interrupting rating. It is used for motor branch circuits and feeders requiring time delay with current limitation. 40A 250VAC, 125VDC, Low Peak Time Delay Dual Element Class RK1 Fuse, Slow Blowing Fuse.
| Product Name | Eaton Bussmann series LPN-RK Class RK1 Fuse |
| Catalog Number | LPN-RK-40SP |
| Rated Amperage | 40A |
| Rated Voltage | 250VAC, 125VDC |
| Product Length | 3 in |
| Product Diameter | 0.81 in |
| Product Weight | 1.2 lb |
| Class | Class RK1 Fuse |
| Voltage Type | AC, DC |
| Breaking Capacity | 300kA RMS Sym. • 100kA DC |
| 3D Model / CAD | stp |
| Connection | Ferrule end x ferrule end |
| Agency Information | UL Listed, Guide JDDZ, File E4273, CSA Certified, Class RK1 per CSA C22.2, No 248.12, Class 1422-02, File 53787, CE |
| Model | Current | Voltage | Class |
|---|---|---|---|
| LPN-RK-1SP | 1A | 250VAC | Class RK1 Fuse |
| LPN-RK-2SP | 2A | 250VAC | Class RK1 Fuse |
| LPN-RK-3SP | 3A | 250VAC | Class RK1 Fuse |
| LPN-RK-4SP | 4A | 250VAC | Class RK1 Fuse |
| LPN-RK-5SP | 5A | 250VAC | Class RK1 Fuse |
| LPN-RK-6SP | 6A | 250VAC | Class RK1 Fuse |
| LPN-RK-8SP | 8A | 250VAC | Class RK1 Fuse |
| LPN-RK-9SP | 9A | 250VAC | Class RK1 Fuse |
| LPN-RK-10SP | 10A | 250VAC | Class RK1 Fuse |
| LPN-RK-12SP | 12A | 250VAC | Class RK1 Fuse |
| LPN-RK-15SP | 15A | 250VAC | Class RK1 Fuse |
| LPN-RK-20SP | 20A | 250VAC | Class RK1 Fuse |
| LPN-RK-25SP | 25A | 250VAC | Class RK1 Fuse |
| LPN-RK-30SP | 30A | 250VAC | Class RK1 Fuse |
| LPN-RK-35SP | 35A | 250VAC | Class RK1 Fuse |
| LPN-RK-40SP | 40A | 250VAC | Class RK1 Fuse |
| LPN-RK-45SP | 45A | 250VAC | Class RK1 Fuse |
| LPN-RK-50SP | 50A | 250VAC | Class RK1 Fuse |
| LPN-RK-60SP | 60A | 250VAC | Class RK1 Fuse |
| LPN-RK-70SP | 70A | 250VAC | Class RK1 Fuse |
| LPN-RK-80SP | 80A | 250VAC | Class RK1 Fuse |
| LPN-RK-90SP | 90A | 250VAC | Class RK1 Fuse |
| LPN-RK-100SP | 100A | 250VAC | Class RK1 Fuse |
| LPN-RK-110SP | 110A | 250VAC | Class RK1 Fuse |
| LPN-RK-125SP | 125A | 250VAC | Class RK1 Fuse |
| LPN-RK-150SP | 150A | 250VAC | Class RK1 Fuse |
| LPN-RK-175SP | 175A | 250VAC | Class RK1 Fuse |
| LPN-RK-200SP | 200A | 250VAC | Class RK1 Fuse |
| LPN-RK-225SP | 225A | 250VAC | Class RK1 Fuse |
| LPN-RK-250SP | 250A | 250VAC | Class RK1 Fuse |
| LPN-RK-300SP | 300A | 250VAC | Class RK1 Fuse |
| LPN-RK-350SP | 350A | 250VAC | Class RK1 Fuse |
| LPN-RK-350SP | 350A | 250VAC | Class RK1 Fuse |
| LPN-RK-400SP | 400A | 250VAC | Class RK1 Fuse |
| LPN-RK-450SP | 450A | 250VAC | Class RK1 Fuse |
| LPN-RK-500SP | 500A | 250VAC | Class RK1 Fuse |
| LPN-RK-600SP | 600A | 250VAC | Class RK1 Fuse |
37 models in the LPN family, sorted by rated current.
Motor branch circuits and feeders requiring time delay with current limitation.
What is the LPN-RK-40SP rated for?
It is rated 250VAC at 40A. The interrupting rating is 300kA RMS Sym. • 100kA DC. It is a Class RK1 Fuse fuse.
What class is this fuse?
Class RK1 Fuse.
Can I replace it with a different class?
No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.
What does the interrupting rating mean?
It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.
How do I verify the part number?
Order by the full catalog number LPN-RK-40SP; suffixes change the terminal, voltage or package.
Where can I find the datasheet?
The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.
Source: manufacturer catalog page for LPN-RK-40SP. Verify ratings against the current datasheet before ordering.