LQW2BAS_0C Murata Wire Wound RF Inductor 2015
LQW2BAS_0C Murata Wire Wound RF Inductor 2015

LQW2BAS_0C Murata Wire Wound RF Inductor 2015

Share
Murata LQW2BAS_0C series inductor — 66 part numbers, case sizes 2015.
    • Product Details
    • Download
    At a Glance
    • 66 part numbers in this series
    • Case size 2015
    • Inductance 2.7 to 1000 nH
    • Operating temperature -40~85℃

    The Murata LQW2BAS_0C series covers 66 part numbers across case sizes 2015. All parts in the series share the same construction and qualification, and differ in the values listed in the table below — so a design can move up or down the range without changing footprint.

    Part Number List

    Part NumberSpecification
    LQW2BAS10NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,10nH ±2%,250MHz
    LQW2BAS10NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,10nH ±5%,250MHz
    LQW2BAS12NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,12nH ±2%,250MHz
    LQW2BAS12NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,12nH ±5%,250MHz
    LQW2BAS15NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,15nH ±2%,250MHz
    LQW2BAS15NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,15nH ±5%,250MHz
    LQW2BAS18NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,18nH ±2%,250MHz
    LQW2BAS18NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,18nH ±5%,250MHz
    LQW2BAS1R0J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,1,000nH ±5%,25MHz
    LQW2BAS22NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,22nH ±2%,250MHz
    LQW2BAS22NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,22nH ±5%,250MHz
    LQW2BAS24NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,24nH ±2%,250MHz
    LQW2BAS24NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,24nH ±5%,250MHz
    LQW2BAS27NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,27nH ±2%,250MHz
    LQW2BAS27NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,27nH ±5%,250MHz
    LQW2BAS2N7J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,2.7nH ±5%,250MHz
    LQW2BAS2N8J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,2.8nH ±5%,250MHz
    LQW2BAS33NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,33nH ±2%,250MHz
    LQW2BAS33NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,33nH ±5%,250MHz
    LQW2BAS36NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,36nH ±2%,250MHz
    LQW2BAS36NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,36nH ±5%,250MHz
    LQW2BAS39NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,39nH ±2%,250MHz
    LQW2BAS39NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,39nH ±5%,250MHz
    LQW2BAS3N0J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,3nH ±5%,250MHz
    LQW2BAS43NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,43nH ±2%,200MHz
    LQW2BAS43NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,43nH ±5%,200MHz
    LQW2BAS47NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,47nH ±2%,200MHz
    LQW2BAS47NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,47nH ±5%,200MHz
    LQW2BAS56NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,56nH ±2%,200MHz
    LQW2BAS56NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,56nH ±5%,200MHz
    LQW2BAS5N6J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,5.6nH ±5%,250MHz
    LQW2BAS68NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,68nH ±2%,200MHz
    LQW2BAS68NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,68nH ±5%,200MHz
    LQW2BAS6N0J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,6nH ±5%,250MHz
    LQW2BAS6N8J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,6.8nH ±5%,250MHz
    LQW2BAS7N5J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,7.5nH ±5%,250MHz
    LQW2BAS82NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,82nH ±2%,150MHz
    LQW2BAS82NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,82nH ±5%,150MHz
    LQW2BAS8N2G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,8.2nH ±2%,250MHz
    LQW2BAS8N2J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,8.2nH ±5%,250MHz
    LQW2BAS91NG0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,91nH ±2%,150MHz
    LQW2BAS91NJ0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,91nH ±5%,150MHz
    LQW2BASR10G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,100nH ±2%,150MHz
    LQW2BASR10J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,100nH ±5%,150MHz
    LQW2BASR11G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,110nH ±2%,150MHz
    LQW2BASR11J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,110nH ±5%,150MHz
    LQW2BASR12G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,120nH ±2%,150MHz
    LQW2BASR12J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,120nH ±5%,150MHz
    LQW2BASR15G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,150nH ±2%,100MHz
    LQW2BASR15J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,150nH ±5%,100MHz
    LQW2BASR18G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,180nH ±2%,100MHz
    LQW2BASR18J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,180nH ±5%,100MHz
    LQW2BASR22G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,220nH ±2%,100MHz
    LQW2BASR22J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,220nH ±5%,100MHz
    LQW2BASR24G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,240nH ±2%,100MHz
    LQW2BASR24J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,240nH ±5%,100MHz
    LQW2BASR27G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,270nH ±2%,100MHz
    LQW2BASR27J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,270nH ±5%,100MHz
    LQW2BASR33G0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,330nH ±2%,100MHz
    LQW2BASR33J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,330nH ±5%,100MHz
    LQW2BASR39J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,390nH ±5%,100MHz
    LQW2BASR47J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,470nH ±5%,50MHz
    LQW2BASR50J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,500nH ±5%,50MHz
    LQW2BASR56J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,560nH ±5%,25MHz
    LQW2BASR68J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,680nH ±5%,25MHz
    LQW2BASR82J0C#2.09m ±0.2m,1.53m ±0.2m,1.42m ±0.1m,820nH ±5%,25MHz

    66 part numbers in this series, sorted by part number.

    Selection Notes

    • Rated current is quoted against two different criteria — inductance drop and temperature rise. The usable current is the lower of the two for your application.
    • DC resistance sets the copper loss. In high-current paths the DCR term can dominate the total loss budget, so compare DCR before inductance tolerance.
    • Shielded construction keeps the field inside the package. Unshielded parts are smaller and cheaper but radiate into neighbouring traces.
    • Saturation behaviour is soft in metal-alloy parts and sharp in ferrite. Choose according to whether the fault current must be limited or simply ridden through.

    Common Questions

    How many part numbers are in the LQW2BAS_0C series?

    66. The table above lists every one, sorted by part number.

    What do the parts in the LQW2BAS_0C series have in common?

    They share the same inductor construction and case-size family; the differences are the electrical values shown per row.

    Where can I find the full specification for a LQW2BAS_0C part?

    Each part number links to Murata's official product page, which carries the detailed specification sheet, reliability data and simulation models.

    Official documentation: LQW2BAS10NG0C# on murata.com — detailed specification sheet, reliability test data and S-parameter / SPICE models.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message