PV-125A-2XL-15 Eaton Bussmann 1500V 125A Class gPV Low Voltage Fuse
PV-125A-2XL-15 Eaton Bussmann 1500V 125A Class gPV Low Voltage Fuse

PV-125A-2XL-15 Eaton Bussmann 1500V 125A Class gPV Low Voltage Fuse

Share
Eaton Bussmann PV-125A-2XL-15 — 1500V 125A Class gPV low voltage fuse, 33 kAIC interrupting.
    • Product Details
    • Download

    PV-125A-2XL-15 Eaton Bussmann 1500V 125A Class gPV Low Voltage Fuse

    At a Glance
    • 1500 Vdc rated voltage, 125 A rated current
    • 33 kAIC interrupting rating
    • Class gPV time-current characteristic
    • With Indicator

    The Eaton Bussmann PV-125A-2XL-15 is a low voltage fuse with 1500 Vdc rated voltage, 125 A rated current, 33 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is with indicator.

    Specifications

    General specifications
    UPC051712374323
    EAN5996516001233
    Product Length/Depth60 mm
    Product Height205 mm
    Product Width81 mm
    Product Weight0.001 g
    Electrical rating
    Amperage Rating125 A
    Voltage rating1500 Vdc
    Interrupt rating33 kAIC
    ClassClass gPV
    Pre arc (I2T)2200
    Watt losses43 W
    Product specifications
    ApplicationPhotovoltiac systems, inverters
    Fuse typePV-2XL
    Fuse indicatorWith Indicator
    Fuse size2XL
    Fitted with:Blade with top indicator
    Compatible fuse holder
    Suitable forSD2XL-S-PV XL Fuse base

    Series Selection Table

    PV-125A-2XL-15 series selection table
    Ampere ratings, dimensions and catalog numbers across the Low Voltage Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-125A-2XL-15?
    1500 Vdc / 125 A, with a 33 kAIC interrupting rating.
    How much fault current can the PV-125A-2XL-15 interrupt?
    33 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-125A-2XL-15?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the PV-125A-2XL-15 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd