PV-15A10F85L Eaton Bussmann 1500V 15A Class gPV Low Voltage Fuse
PV-15A10F85L Eaton Bussmann 1500V 15A Class gPV Low Voltage Fuse

PV-15A10F85L Eaton Bussmann 1500V 15A Class gPV Low Voltage Fuse

Share
Eaton Bussmann PV-15A10F85L — 1500V 15A Class gPV low voltage fuse, 30 kAIC interrupting.
    • Product Details
    • Download

    PV-15A10F85L Eaton Bussmann 1500V 15A Class gPV Low Voltage Fuse

    At a Glance
    • 1500 Vdc rated voltage, 15 A rated current
    • 30 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Non Indicating

    The Eaton Bussmann PV-15A10F85L is a low voltage fuse with 1500 Vdc rated voltage, 15 A rated current, 30 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is non indicating.

    Specifications

    General specifications
    UPC051712698412
    EAN5027590505499
    Product Length/Depth85 mm
    Product Height10 mm
    Product Width10 mm
    Product Weight19 g
    Electrical rating
    Amperage Rating15 A
    Voltage rating1500 Vdc
    Interrupt rating30 kAIC
    ClassClass gPV
    Pre arc (I2T)42
    Watt losses3.6 W
    Product specifications
    ApplicationPhotovoltaic systems, inverters ,Photovoltaic strings
    Fuse typePV-A10F85L
    Fuse indicatorNon Indicating
    Fuse size10 x 85 mm
    Compatible fuse holder
    Suitable forCHPV15L85 Fuse holder

    Standards Reference

    • IEC 60269-6

    Series Selection Table

    PV-15A10F85L series selection table
    Ampere ratings, dimensions and catalog numbers across the Low Voltage Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-15A10F85L?
    1500 Vdc / 15 A, with a 30 kAIC interrupting rating.
    How much fault current can the PV-15A10F85L interrupt?
    30 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-15A10F85L?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    Which standards does the PV-15A10F85L comply with?
    It is referenced against IEC 60269-6 in the manufacturer data.
    How should I select the PV-15A10F85L for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.