PV-160A-01XL Eaton Bussmann 1000V 160A Class gPV Solar PV Fuse
PV-160A-01XL Eaton Bussmann 1000V 160A Class gPV Solar PV Fuse

PV-160A-01XL Eaton Bussmann 1000V 160A Class gPV Solar PV Fuse

Share
Eaton Bussmann PV-160A-01XL — 1000V 160A Class gPV solar pv fuse, 50 kAIC interrupting. For DC string protection in photovoltaic arrays.
    • Product Details
    • Download

    PV-160A-01XL Eaton Bussmann 1000V 160A Class gPV Solar PV Fuse

    At a Glance
    • 1000 Vdc rated voltage, 160 A rated current
    • 50 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Top fuse status indicator

    The Eaton Bussmann PV-160A-01XL is a solar pv fuse with 1000 Vdc rated voltage, 160 A rated current, 50 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is top fuse status indicator.

    Specifications

    General specifications
    UPC051712371995
    EAN5996516000359
    Product Length/Depth218 mm
    Product Height61 mm
    Product Width84 mm
    Product Weight840 g
    Electrical rating
    Amperage Rating160 A
    Voltage rating1000 Vdc
    Interrupt rating50 kAIC
    ClassClass gPV
    Pre arc (I2T)3900
    Watt losses44 W
    Product specifications
    ApplicationPhotovoltaic array combiners and disconnects
    Fuse typePV-01XL
    Fuse indicatorTop fuse status indicator
    Fuse size01XL
    Fitted with:Blade without bolt holes
    Compatible fuse holder
    Suitable forSD1XL-S-PV XL Fuse base

    Series Selection Table

    PV-160A-01XL series selection table
    Ampere ratings, dimensions and catalog numbers across the Solar PV Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • PV fuses see continuous DC and elevated combiner-box ambients; derate the ampere rating for temperature rather than reusing the AC figure.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-160A-01XL?
    1000 Vdc / 160 A, with a 50 kAIC interrupting rating.
    How much fault current can the PV-160A-01XL interrupt?
    50 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-160A-01XL?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the PV-160A-01XL for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.