PV-16A10F85L Eaton Bussmann 1500V 16A Class gPV Solar PV Fuse
PV-16A10F85L Eaton Bussmann 1500V 16A Class gPV Solar PV Fuse

PV-16A10F85L Eaton Bussmann 1500V 16A Class gPV Solar PV Fuse

Share
Eaton Bussmann PV-16A10F85L — 1500V 16A Class gPV solar pv fuse, 30 kAIC interrupting. For DC string protection in photovoltaic arrays.
    • Product Details
    • Download

    PV-16A10F85L Eaton Bussmann 1500V 16A Class gPV Solar PV Fuse

    At a Glance
    • 1500 Vdc rated voltage, 16 A rated current
    • 30 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Non Indicating

    The Eaton Bussmann PV-16A10F85L is a solar pv fuse with 1500 Vdc rated voltage, 16 A rated current, 30 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is non indicating.

    Specifications

    General specifications
    UPC051712698429
    EAN5027590505604
    Product Length/Depth83.8 mm
    Product Height9.6 mm
    Product Width9.6 mm
    Product Weight0.001 g
    Electrical rating
    Amperage Rating16 A
    Voltage rating1500 Vdc
    Interrupt rating30 kAIC
    ClassClass gPV
    Pre arc (I2T)48
    Watt losses3.5 W
    Product specifications
    ApplicationPhotovoltaic systems, inverters ,Photovoltaic strings
    Fuse typePV-A10F85L
    Fuse indicatorNon Indicating
    Fuse size10 x 85 mm
    Compatible fuse holder
    Suitable forCHPV15L85 Fuse holder

    Standards Reference

    • IEC 60269-6

    Series Selection Table

    PV-16A10F85L series selection table
    Ampere ratings, dimensions and catalog numbers across the Solar PV Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • PV fuses see continuous DC and elevated combiner-box ambients; derate the ampere rating for temperature rather than reusing the AC figure.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-16A10F85L?
    1500 Vdc / 16 A, with a 30 kAIC interrupting rating.
    How much fault current can the PV-16A10F85L interrupt?
    30 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-16A10F85L?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    Which standards does the PV-16A10F85L comply with?
    It is referenced against IEC 60269-6 in the manufacturer data.
    How should I select the PV-16A10F85L for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd