PV-250A-2XL Eaton Bussmann 1000V 250A Class gPV Solar PV Fuse
PV-250A-2XL Eaton Bussmann 1000V 250A Class gPV Solar PV Fuse

PV-250A-2XL Eaton Bussmann 1000V 250A Class gPV Solar PV Fuse

Share
Eaton Bussmann PV-250A-2XL — 1000V 250A Class gPV solar pv fuse, 33 kAIC interrupting. For DC string protection in photovoltaic arrays.
    • Product Details
    • Download

    PV-250A-2XL Eaton Bussmann 1000V 250A Class gPV Solar PV Fuse

    At a Glance
    • 1000 Vdc rated voltage, 250 A rated current
    • 33 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Top fuse status indicator

    The Eaton Bussmann PV-250A-2XL is a solar pv fuse with 1000 Vdc rated voltage, 250 A rated current, 33 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is top fuse status indicator.

    Specifications

    General specifications
    UPC051712372077
    EAN5996516000427
    Product Length/Depth61 mm
    Product Height61 mm
    Product Width205 mm
    Product Weight1423 g
    Electrical rating
    Amperage Rating250 A
    Voltage rating1000 Vdc
    Interrupt rating33 kAIC
    ClassClass gPV
    Pre arc (I2T)7721
    Watt losses70 W
    Product specifications
    ApplicationPhotovoltaic array combiners and disconnects
    Fuse typePV-2XL
    Fuse indicatorTop fuse status indicator
    Fuse size2XL
    Fitted with:Blade without bolt holes
    Compatible fuse holder
    Suitable forSD2XL-S-PV XL Fuse base

    Series Selection Table

    PV-250A-2XL series selection table
    Ampere ratings, dimensions and catalog numbers across the Solar PV Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • PV fuses see continuous DC and elevated combiner-box ambients; derate the ampere rating for temperature rather than reusing the AC figure.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-250A-2XL?
    1000 Vdc / 250 A, with a 33 kAIC interrupting rating.
    How much fault current can the PV-250A-2XL interrupt?
    33 kAIC. The available fault current at the installation point must not exceed this value.