PV-315A-3L-B-15 Eaton Bussmann 1500V 315A Class gPV Solar PV Fuse
PV-315A-3L-B-15 Eaton Bussmann 1500V 315A Class gPV Solar PV Fuse

PV-315A-3L-B-15 Eaton Bussmann 1500V 315A Class gPV Solar PV Fuse

Share
Eaton Bussmann PV-315A-3L-B-15 — 1500V 315A Class gPV solar pv fuse, 100 kAIC interrupting. For DC string protection in photovoltaic arrays.
    • Product Details
    • Download

    PV-315A-3L-B-15 Eaton Bussmann 1500V 315A Class gPV Solar PV Fuse

    At a Glance
    • 1500 Vdc rated voltage, 315 A rated current
    • 100 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Centre fuse status indicator

    The Eaton Bussmann PV-315A-3L-B-15 is a solar pv fuse with 1500 Vdc rated voltage, 315 A rated current, 100 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is centre fuse status indicator.

    Specifications

    General specifications
    UPC051712374552
    EAN5996516001455
    Product Length/Depth201.4 mm
    Product Height91 mm
    Product Width91 mm
    Product Weight1614 g
    Electrical rating
    Amperage Rating315 A
    Voltage rating1500 Vdc
    Interrupt rating100 kAIC
    ClassClass gPV
    Pre arc (I2T)150000
    Watt losses52 W
    Product specifications
    ApplicationPhotovoltaic array combiners and disconnects
    Fuse typePV-3L-B-15
    Fuse indicatorCentre fuse status indicator
    Fuse size3L
    Fitted with:Side indicator

    Series Selection Table

    PV-315A-3L-B-15 series selection table
    Ampere ratings, dimensions and catalog numbers across the Solar PV Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • PV fuses see continuous DC and elevated combiner-box ambients; derate the ampere rating for temperature rather than reusing the AC figure.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-315A-3L-B-15?
    1500 Vdc / 315 A, with a 100 kAIC interrupting rating.
    How much fault current can the PV-315A-3L-B-15 interrupt?
    100 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-315A-3L-B-15?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the PV-315A-3L-B-15 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.