PV-350A-3L-B Eaton Bussmann 1000V 350A Class gPV Solar PV Fuse
PV-350A-3L-B Eaton Bussmann 1000V 350A Class gPV Solar PV Fuse

PV-350A-3L-B Eaton Bussmann 1000V 350A Class gPV Solar PV Fuse

Share
Eaton Bussmann PV-350A-3L-B — 1000V 350A Class gPV solar pv fuse, 50 kAIC interrupting. For DC string protection in photovoltaic arrays.
    • Product Details
    • Download

    PV-350A-3L-B Eaton Bussmann 1000V 350A Class gPV Solar PV Fuse

    At a Glance
    • 1000 Vdc rated voltage, 350 A rated current
    • 50 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Top fuse status indicator

    The Eaton Bussmann PV-350A-3L-B is a solar pv fuse with 1000 Vdc rated voltage, 350 A rated current, 50 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is top fuse status indicator.

    Specifications

    General specifications
    UPC051712374514
    EAN5996516001196
    Product Length/Depth217 mm
    Product Height82 mm
    Product Width94 mm
    Product Weight1200 g
    Electrical rating
    Amperage Rating350 A
    Voltage rating1000 Vdc
    Interrupt rating50 kAIC
    ClassClass gPV
    Pre arc (I2T)30885
    Watt losses65 W
    Product specifications
    ApplicationPhotovoltaic systems, inverters, solar applications
    Fuse typePV-3L-B
    Fuse indicatorTop fuse status indicator
    Fuse size3L
    Fitted with:Blade with bolt holes

    Series Selection Table

    PV-350A-3L-B series selection table
    Ampere ratings, dimensions and catalog numbers across the Solar PV Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • PV fuses see continuous DC and elevated combiner-box ambients; derate the ampere rating for temperature rather than reusing the AC figure.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-350A-3L-B?
    1000 Vdc / 350 A, with a 50 kAIC interrupting rating.
    How much fault current can the PV-350A-3L-B interrupt?
    50 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-350A-3L-B?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the PV-350A-3L-B for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.