PV-355A-3L-B-15 Eaton Bussmann 1500V 355A Class gPV Low Voltage Fuse
PV-355A-3L-B-15 Eaton Bussmann 1500V 355A Class gPV Low Voltage Fuse

PV-355A-3L-B-15 Eaton Bussmann 1500V 355A Class gPV Low Voltage Fuse

Share
Eaton Bussmann PV-355A-3L-B-15 — 1500V 355A Class gPV low voltage fuse, 100 kAIC interrupting.
    • Product Details
    • Download

    PV-355A-3L-B-15 Eaton Bussmann 1500V 355A Class gPV Low Voltage Fuse

    At a Glance
    • 1500 Vdc rated voltage, 355 A rated current
    • 100 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Centre fuse status indicator

    The Eaton Bussmann PV-355A-3L-B-15 is a low voltage fuse with 1500 Vdc rated voltage, 355 A rated current, 100 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is centre fuse status indicator.

    Specifications

    General specifications
    UPC051712374569
    EAN5996516001462
    Product Length/Depth91 mm
    Product Height91 mm
    Product Width201.4 mm
    Product Weight1614 g
    Electrical rating
    Amperage Rating355 A
    Voltage rating1500 Vdc
    Interrupt rating100 kAIC
    ClassClass gPV
    Pre arc (I2T)195000
    Watt losses59 W
    Product specifications
    ApplicationPhotovoltaic array combiners and disconnects
    Fuse typePV-3L-B-15
    Fuse indicatorCentre fuse status indicator
    Fuse size3L
    Fitted with:Side indicator

    Series Selection Table

    PV-355A-3L-B-15 series selection table
    Ampere ratings, dimensions and catalog numbers across the Low Voltage Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-355A-3L-B-15?
    1500 Vdc / 355 A, with a 100 kAIC interrupting rating.
    How much fault current can the PV-355A-3L-B-15 interrupt?
    100 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-355A-3L-B-15?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the PV-355A-3L-B-15 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message