PV-400A-3L Eaton Bussmann 1000V 400A Class gPV Low Voltage Fuse
PV-400A-3L Eaton Bussmann 1000V 400A Class gPV Low Voltage Fuse

PV-400A-3L Eaton Bussmann 1000V 400A Class gPV Low Voltage Fuse

Share
Eaton Bussmann PV-400A-3L — 1000V 400A Class gPV low voltage fuse, 50 kAIC interrupting.
    • Product Details
    • Download

    PV-400A-3L Eaton Bussmann 1000V 400A Class gPV Low Voltage Fuse

    At a Glance
    • 1000 Vdc rated voltage, 400 A rated current
    • 50 kAIC interrupting rating
    • Class gPV time-current characteristic
    • Top fuse status indicator

    The Eaton Bussmann PV-400A-3L is a low voltage fuse with 1000 Vdc rated voltage, 400 A rated current, 50 kAIC interrupting capacity, carrying a Class gPV time-current characteristic. Construction is top fuse status indicator.

    Specifications

    General specifications
    UPC051712372190
    EAN5996516000588
    Product Length/Depth75 mm
    Product Height205 mm
    Product Width85 mm
    Product Weight1978 g
    Electrical rating
    Amperage Rating400 A
    Voltage rating1000 Vdc
    Interrupt rating50 kAIC
    ClassClass gPV
    Pre arc (I2T)44500
    Watt losses82 W
    Product specifications
    ApplicationPhotovoltaic systems, inverters, Photovoltaic array combiners and disconnects
    Fuse typePV-3L
    Fuse indicatorTop fuse status indicator
    Fuse size3L
    Fitted with:Blade without bolt holes
    Compatible fuse holder
    Suitable forSD3L-S-PV XL Fuse base

    Series Selection Table

    PV-400A-3L series selection table
    Ampere ratings, dimensions and catalog numbers across the Low Voltage Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-400A-3L?
    1000 Vdc / 400 A, with a 50 kAIC interrupting rating.
    How much fault current can the PV-400A-3L interrupt?
    50 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-400A-3L?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the PV-400A-3L for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd