PV-63ANH1-B Eaton Bussmann 1000V 63A Class gPV Fuse
PV-63ANH1-B Eaton Bussmann 1000V 63A Class gPV Fuse

PV-63ANH1-B Eaton Bussmann 1000V 63A Class gPV Fuse

Share
Eaton Bussmann PV-63ANH1-B — 1000V 63A Class gPV fuse, 50 kA interrupting.
    • Product Details
    • Download

    PV-63ANH1-B Eaton Bussmann 1000V 63A Class gPV Fuse

    At a Glance
    • 1000 Vdc rated voltage, 63 A rated current
    • 50 kA interrupting rating
    • Class gPV time-current characteristic

    The Eaton Bussmann PV-63ANH1-B is a fuse with 1000 Vdc rated voltage, 63 A rated current, 50 kA interrupting capacity, carrying a Class gPV time-current characteristic.

    Specifications

    General specifications
    UPC051712531610
    EAN5027590411905
    Product Length/Depth135 mm
    Product Height53 mm
    Product Width40 mm
    Product Weight0.001 g
    Electrical data
    Amperage Rating63 A
    Voltage rating1000 Vdc
    Voltage typeDC
    Watt losses12 W
    Breaking capacity50 kA
    ClassClass gPV
    Product specification
    Fuse sizeNH1
    Fitted with:Blade with bolt holes

    Series Selection Table

    PV-63ANH1-B series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann PV-63ANH1-B?
    1000 Vdc / 63 A, with a 50 kA interrupting rating.
    How much fault current can the PV-63ANH1-B interrupt?
    50 kA. The available fault current at the installation point must not exceed this value.
    What does Class gPV mean for the PV-63ANH1-B?
    Class gPV defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the PV-63ANH1-B for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products